- Adjusted light control logic to handle RGB settings and state changes more effectively.
- Introduced a new substitution `board_has_rgb` to indicate RGB functionality availability.
- Removed the deprecated `board_options_rgb_led_status.yaml` file.
- Enhanced CAN bus and RS485 configurations to include LED control based on device status.
- Updated T-Connect and YamBMS behaviour documentation
The `bms_ids` variable allows to provide an array of BMS IDs that are connected to this shunt.
If one or more BMS from this array are offline, the shunt is not used anymore (Combine = Disabled). This avoids returning a wrong SOC when not all batteries are online/available anymore.
If the BMS goes online again, the shunt is then used again.
This variable is optional. If not provided, the shunt work independently from the BMS online status.
Examples:
```
bms_ids: '{1}'
bms_ids: '{1, 2}'
bms_ids: '{4, 5, 6}'
```