Sleeper85 3e596ea82a Reworked the update and telemetry services
- update and telemetry are now gated independently by substitution;
  var_service and its Update service switch are removed
- the uptime text sensor is published by its source instead of polling
  it, which fixes the 24855d readings that reached the telemetry, and
  the raw seconds are now sent instead of the formatted string
- the MAC address is replaced by a salted SHA-256, derived identically
  server side so no pairing window is needed
2026-11-08 23:08:33 +01:00
Sleeper85 9dd22fa56b Inferred equalizing for BMS that do not report a balancing flag
Some BMS balance their cells but never expose a balancing flag, so
`bms_equalizing` stays false and the core cannot tell a pack that is still
balancing from one that has finished. This is not cosmetic : while
equalizing is true, yambms_core.yaml stops the Cut-Off timer and lets the
charge run to the EOC timer instead of terminating early.

bms_options_fake_equalizing.yaml infers that flag from the pack itself. No
absolute cell voltage is hardcoded : the anchor is bulk_voltage / cell
count, the same derivation as cell_bulk_v in yambms_core.yaml, so it
follows `yambms_battery_chemistry`, the cell count and the configured bulk
voltage automatically.

  START when BOTH are true
    max cell >= cell_bulk_v                     the pack is at the setpoint
    AND (max - min) >= trigger voltage          its own balancing threshold

  STOP when EITHER is true
    max cell <  cell_bulk_v - hysteresis        the pack dropped off the setpoint
    OR (max - min) <  trigger - delta hyst.     the spread closed back below it

Only two deltas and one offset are configurable, and none of the three
depends on the chemistry - LFP, Li-ion and LTO all want the same few tens
of mV. The absolute anchor they hang off comes from the core, for free.

The delta condition is what keeps this honest : a pack that reaches the
setpoint perfectly balanced has nothing to equalize, so it reports false
and the Cut-Off timer does its job. A plain voltage comparison would report
balancing forever and terminate every charge on the EOC timer.

It extends bms<id>_bms_equalizing, the raw BMS flag, and not the combined
bms<id>_equalizing sensor. bms_base_balancer.yaml is therefore neither
modified nor duplicated, and keeps giving an external balancer priority
whenever one is online : the inference only applies when no balancer
reports for this pack.

This commit only adds the package. Nothing includes it yet, so no existing
configuration changes behaviour. Candidates sharing the same case are
Seplos V3, Seplos V1/V2, EG4 LL V2 and JK RS485 DISPLAY, whose
bms_equalizing is a hardcoded `return false;`.
2026-11-08 23:08:33 +01:00
Sleeper85 17360765d4 Update Changelog.md 2026-11-08 23:08:33 +01:00
Sleeper85 7fc55192c8 Updated Auto CVL changelog 1.8.0 2026-11-08 23:08:33 +01:00
Sleeper85 cb3b0eedba Installed Battery Capacity now follows a capacity change at runtime
The installed total was accumulated once per BMS per boot, latched by
bms<id>_combined_once, so a BMS reconfigured with a different capacity
kept contributing its boot value until the next reboot.

Each BMS now remembers the last capacity it contributed in
bms<id>_installed_capacity and applies only the difference to the total.

- the update runs in the can_be_combined branch, so an offline BMS simply
  stops updating its contribution, which stays in the total : the installed
  capacity still never shrinks on an uncombine, as before
- a BMS coming back with a different capacity is applied as a delta, with
  no double counting
- combined_once had no other reader and is removed

The total is deliberately not turned into a per-round accumulator reset in
the Global vars reset block like the other totals : its sensor is polled
independently of STEP 2 and its state is written straight into CAN frame
0x379 with no has_state() guard, so a transient zero would announce 0 Ah of
installed capacity to the inverter. See Design_decisions.md.
2026-11-08 23:08:33 +01:00
Sleeper85 0f7bf94111 Added KS BMS support #151 2026-11-08 23:08:33 +01:00
Sleeper85 b7bb2e93ea Moved Auto CCL Current Taper section 2026-11-08 23:08:33 +01:00
Sleeper85 e4b8aacc0a Fixed 6h reboot on networks that filter the ESP32 outbound traffic
http_request runs on the loop task, which has a 4s budget before the
5s task WDT panics. A dropped connect() blocks for 4.5s (the ESPHome
default timeout) and a filtered port 53 blocks for a fixed 7s, which
timeout does not cover.

- timeout 3s and watchdog_timeout 60s cover the two blocking paths
- a failure counter stops the service after 3 network-level failures,
  instead of freezing the loop 14s every 6h forever
- the POST is now skipped when the GET failed

Reproduced and measured on OPNsense.
See Design_decisions.md.
2026-11-08 23:08:33 +01:00
Sleeper85 9f90436849 Multi-inverter support, division of CCL/DCL by the number of inverters/chargers 2026-11-08 23:08:33 +01:00
Sleeper85 4d4d11e832 Auto CVL - Float / Stop (suspended) 2026-11-08 23:08:32 +01:00
Andrew Rankin 40daa229b5 Update EG4 LL-V2 component to v1.1.0 (fixes zero-value BMS readings) (#315)
* Update EG4 LL-V2 component to v1.1.0

Fixes RAR/esphome-eg4-bms#7: some EG4 LL-V2 units intermittently answer
with a CRC-valid function-03 response whose register data area is
entirely zero. The component published those zeroes as a real reading,
collapsing SoC, pack voltage and capacity for one poll cycle.

v1.1.0 rejects implausible blocks and no longer lets them refresh the
online tracker, so a unit stuck returning zeroes now goes offline
instead of reporting a flat-zero battery.

No YamBMS-side changes are required: neither EG4 package uses the
removed designed_capacity sensor, and both already use the
cell_average_voltage key.
2026-11-08 23:08:32 +01:00
Sleeper85 da0e5c8c23 Updated secrets.yaml examples 2026-11-08 23:08:32 +01:00
Sleeper85 bfa36fb15f Added dev README 2026-11-08 23:08:32 +01:00
Sleeper85 2cdc61e8b4 Fixed Auto CVL Float lockup at Rebulk threshold
Rewrote Auto CVL from template sensor lambdas to interval
lambdas, splitting each into a value sensor and a delta sensor.

Fixed a bug confirmed in production: Auto CVL's Float floor coincided
exactly with the Rebulk V. threshold, letting it trigger its own rebulk.
The floor is now capped relative to the live target instead of a fixed
chemistry constant, the Float/Stop integral term can no longer get stuck
once clamped, and PI state now resets when crossing the Bulk <-> Float/Stop
boundary.
2026-11-08 23:08:32 +01:00
Sleeper85 717503e73a Added HA entities cleanup readme 2026-11-08 23:08:32 +01:00
Sleeper85 485fd8f7a4 YamBMS 1.8.0 changelog 2026-11-08 23:08:32 +01:00
Sleeper85 4bf2362723 Delete YamBMS_multi-node_RS485_modbus_solution.md 2026-11-08 23:08:32 +01:00
Sleeper85 20dd8bcd23 Updated README 2026-11-08 23:08:32 +01:00
Sleeper85 ace139dec0 Moved README 2026-11-08 23:08:32 +01:00
Sleeper85 fd4ee6e903 Current Taper - Compliance with YamBMS core 1.8.0
See Changelog_Auto_CCL_Current_Taper_1.1.2.md
2026-11-08 23:08:32 +01:00
Sleeper85 ab3633b0d9 Auto CVL - Compliance with YamBMS core 1.8.0
Updated to support `Float` and `Stop` CVL.
See Changelog_YamBMS_1.8.0_Auto_CVL.md
2026-11-08 23:08:32 +01:00
Sleeper85 31314847d9 YamBMS core 1.8.0 - CVL, CCL and DCL code improvements 2026-11-08 23:08:32 +01:00
haysdb a927f7c9b3 Auto CCL Current Taper (#303)
This YAML file implements the Auto CCL Current Taper feature for the YamBMS project, defining various parameters and logic for charge current tapering during battery charging.
2026-11-08 23:08:32 +01:00
Sleeper85 80ccf671f3 Create Understanding_ESPHome_Modbus.md 2026-11-08 23:08:32 +01:00
Sleeper85 c82af08d3c Updated multi-node modbus default settings + documentation #310 2026-11-08 23:08:32 +01:00
Sleeper85 c9162e659e Updated default PSRAM options (ESP-IDF 5.5+) + documentation 2026-11-08 23:08:32 +01:00
Sleeper85 9ddd618da7 Added loop_task_stack_size option + documentation #306 2026-11-08 23:08:32 +01:00
Sebastian 59f844d650 Add grace period to Auto EOC (#290)
* Add grace period to Auto EOC
* Smooth remaining capacity for Auto EOC
2026-11-08 23:08:32 +01:00
Sleeper85 978c634eb9 Improved YamBMS 1.7.1 Cut-Off charging logic 2026-11-08 23:08:32 +01:00
Sleeper85 54febc11b3 Create How_to_perform_a_PR_to_the_dev_branch.md 2026-11-08 23:08:31 +01:00
Sleeper85 ace919a175 Improved README after adding max currend c-rate based limit 2026-11-08 23:08:31 +01:00
Sleeper85 7df415153b Create RS485-protocol-pylon-low-voltage-V3.5-20190807.pdf 2026-07-11 00:05:53 +02:00
Sleeper85 e5631954ec Update Changelog.md 2026-06-29 01:17:11 +02:00
Sleeper85 f764fa73e6 Update Troubleshooting.md 2026-06-29 01:17:05 +02:00
Sebastian 62791addde Add support for Rebulk Days (#259)
This adds `Rebulk Days` which specify the number of days since last full charge to enter `Bulk` again. It works like `Rebulk SoC` or `Rebulk V.` and can be disabled by setting it to 0 days.
2026-03-16 17:38:28 +01:00
Sebastian c5d9fdd66a Auto EOC: Factor in Auto SoC Limit for battery capacity calculation (#258) 2026-03-15 11:26:38 +01:00
Sebastian 11464f4ad2 Improve Auto SoC Limit function (#256)
- Disable when `Force Bulk` is active
- Disable when charging status is not `Bulk` or `Float`
- Add additional status messages to make clear what happens
2026-03-15 11:25:36 +01:00
Sebastian 78aff46702 Add support for Auto SoC Limit (#255) 2026-03-11 23:17:22 +01:00
Sleeper85 fc741b942d Create STUDY_2018_Analysis_and_modeling_of_calendar_aging_of_a_commercial_LiFePO4_graphite_cell.md 2026-03-11 21:40:19 +01:00
Sleeper85 5841192281 Added Ecoworthy BMS (RS485) 2026-02-16 11:24:26 +01:00
Sleeper85 f38f12df00 Simplified list of supported inverters 2026-02-16 11:02:54 +01:00
Sleeper85 6fb2710095 Added canbus_extended_ack for Schneider XW Pro 2026-02-16 10:06:20 +01:00
Sleeper85 d5c4e2b3e8 Improved readme : CAN bus link + Warning & Alarms 2026-02-15 20:08:01 +01:00
Sleeper85 dbb7dcd779 Delete CANBUS_protocol.md 2026-02-09 08:29:46 +01:00
MrPabloUK 6634abed64 Fix link to LilyGo T-Connect in README (#207) 2026-02-06 00:55:20 +01:00
MrPabloUK 447a18b832 Component Fault Registry & Advanced LED Control (#194) 2026-02-05 09:26:49 +01:00
Sleeper85 d4e0ff02d6 Fixed issue #187 2026-02-02 14:25:04 +01:00
Sleeper85 54661754df Updated CAN bus link readme 2026-01-31 14:42:43 +01:00
MrPabloUK d44f3921dd Added a new board_options_led_control.yaml file to manage LED behavior based on status sensors (#179)
- Adjusted light control logic to handle RGB settings and state changes more effectively.
- Introduced a new substitution `board_has_rgb` to indicate RGB functionality availability.
- Removed the deprecated `board_options_rgb_led_status.yaml` file.
- Enhanced CAN bus and RS485 configurations to include LED control based on device status.
- Updated T-Connect and YamBMS behaviour documentation
2026-01-30 19:31:36 +01:00
Sebastian a9c8443a66 Provide connected BMS IDs to shunt (#158)
The `bms_ids` variable allows to provide an array of BMS IDs that are connected to this shunt.

If one or more BMS from this array are offline, the shunt is not used anymore (Combine = Disabled). This avoids returning a wrong SOC when not all batteries are online/available anymore.

If the BMS goes online again, the shunt is then used again.

This variable is optional. If not provided, the shunt work independently from the BMS online status.

Examples:
```
bms_ids: '{1}'
bms_ids: '{1, 2}'
bms_ids: '{4, 5, 6}'
```
2026-01-26 21:31:46 +01:00