Files
esphome-yambms/documents/README
Sleeper85 e569bfbac9 CAN 0x35A - Send inactive alarms and warnings as OK (10), not 00
Each alarm and warning of 0x35A is a 2-bit field : 1 is active, 2 is
inactive (OK), 0 and 3 mean not supported. YamBMS only set the active
bit and left 00 otherwise, so an inverter read every field that was not
in alarm as "not supported" instead of OK.

Every field is now written explicitly, active or inactive, and a frame
with no alarm is AA AA AA 02 AA AA AA 02, which is what a BYD battery
sends at rest. The reserved fields of bytes 3 and 7 stay at 0. The
mapping of the YamBMS bits is unchanged.

The frame is sent by PYLON V2, SMA and Victron. SMA calls the two bits
"arrive" and "leave", with the same meaning. The alarms are only
displayed and logged by the inverter, they do not change how it charges.

Design_decisions.md records why OK must never be sent as 0.